Installation Guide

12 Part Number: 000014141 Rev 03 2/18
Installation Section 2
Minimum/Maximum Temperatures
Model
Minimum Air
Temperature
Maximum Air
Temperature
All Ice
Machine
Head
Sections
35°F
2°C
110°F
43°C
All Remote
Condensers
-20°F
-29°C
120°F
49°C
QuietQube
Condensing
Units
CVDF0600
CVDF0900
CVDT1200
CVDF2100
-20°F
-29°C
120°F
49°C
CVDF1400
CVDF1800
-20°F
-29°C
130°F
54°C
Ice Machine Heat of Rejection
Ice Machine Heat of Rejection
Series
Air
Conditioning
Peak
IF0300 4600 5450
IT0420 *3800 *6000
IT0450 *5400 *6300
IT0500 *6100 *6900
IF0600 9000 13900
IT0620 *9000 *13900
IF0900 13000 16000
IT1200 *20700 *24500
IT1500 23000 27000
IT1900 26100 30500
* Data marked with an asterisk is preliminary
and subject to change.
Use this information when:
Sizing air conditioning equipment where
self-contained air-cooled ice machines
are installed.
Determining the load on a cooling tower.
Use the peak figure for sizing the load.