Service Manual
Table Of Contents
- Safety Notices
- Definitions
- General Information
- Installation
- Stacking Two Ice Machines on a Single Storage Bin
- Location of Ice Machine
- Clearance Requirements
- Dual Evaporator Model Installation on a Manitowoc Bin
- Ice Machine on a Dispenser Installation
- Water Supply and Drains
- Lineset Applications
- QuietQube® Remote Condensing Unit
- Additional Refrigerant Charge For 51' to 100' Line Sets
- Maintenance
- Operation
- Menu Navigation
- Component Check Procedures
- Control Board, Display And Touchscreen
- Operating an ice machine without a Touchscreen
- Control Board Relay Test
- Programming A Replacement Control Board
- USB Flash Drive Specifications and Formatting
- Exporting Data to a Flash Drive
- Upgrading Firmware with a Flash Drive
- Main Fuse
- Bin Switch
- Water Level Control Circuitry
- Ice Thickness Probe (Initiates Harvest)
- Bin Level Probe
- Thermistors
- High Pressure Cutout (HPCO) Control
- Low Pressure Cutout (LPCO) Control
- Compressor Time Delay
- Fan Cycle Control
- Harvest Assist Air Pump
- Compressor Electrical Diagnostics
- Diagnosing Start Components
- Refrigeration Components
- Recovery/Evacuation/Charging Procedures QuietQube® Models
- System Contamination Clean-Up
- Total System Refrigerant Charge QuietQube® CVD Models
- Control Board, Display And Touchscreen
- Charts
- Diagrams
Part Number: 000015431 Rev 02 6/20 41
Step 1 Open the front door to access the evaporator
compartment. Ice must not be on the evaporator during
the descaling/sanitize cycle. Follow one of the methods
below:
• Press the power switch at the end of a harvest cycle
after ice falls from the evaporator(s).
• Press the power switch and allow the ice to melt.
• Use the touchscreen to initiate a manual harvest cycle.
Notice
Never use anything to force ice from the evaporator.
Damage may result.
Step 2 Remove all ice from the bin/dispenser.
Step 3 Press the Clean button and select “Turn off
when complete”. Water will flow through the water dump
valve and down the drain. Wait approximately 1 minute
until the water trough refills and the display indicates Add
Chemical. Add the proper amount of ice machine cleaner/
descaler to the water trough by pouring between the
water curtain and evaporator, then confirm the chemical
was added.
NOTE: There is a 10 minute time limit to confirm chemical
was added.
• Confirmation is pushed within 10 minutes - The ice
machine will start a 10 minute wash cycle, followed by
6 rinse and flush cycles.
• Confirmation is not pushed within 10 minutes - The ice
machine will skip the 10 minute wash cycle and start 6
rinse and flush cycles.
Step 4
Model Amount of Cleaner/Descaler
IF0600C/IBF0620C/IBF0820C
IF0900C/IBT1020C/IT1200C
5 ounces (150 ml)
IF1400C/IF1800C/IF2100C 9 ounces (265 ml)