Service Manual
Table Of Contents
- Safety Notices
- Definitions
- General Information
- Installation
- Stacking Two Ice Machines on a Single Storage Bin
- Location of Ice Machine
- Clearance Requirements
- Dual Evaporator Model Installation on a Manitowoc Bin
- Ice Machine on a Dispenser Installation
- Water Supply and Drains
- Lineset Applications
- QuietQube® Remote Condensing Unit
- Additional Refrigerant Charge For 51' to 100' Line Sets
- Maintenance
- Operation
- Menu Navigation
- Component Check Procedures
- Control Board, Display And Touchscreen
- Operating an ice machine without a Touchscreen
- Control Board Relay Test
- Programming A Replacement Control Board
- USB Flash Drive Specifications and Formatting
- Exporting Data to a Flash Drive
- Upgrading Firmware with a Flash Drive
- Main Fuse
- Bin Switch
- Water Level Control Circuitry
- Ice Thickness Probe (Initiates Harvest)
- Bin Level Probe
- Thermistors
- High Pressure Cutout (HPCO) Control
- Low Pressure Cutout (LPCO) Control
- Compressor Time Delay
- Fan Cycle Control
- Harvest Assist Air Pump
- Compressor Electrical Diagnostics
- Diagnosing Start Components
- Refrigeration Components
- Recovery/Evacuation/Charging Procedures QuietQube® Models
- System Contamination Clean-Up
- Total System Refrigerant Charge QuietQube® CVD Models
- Control Board, Display And Touchscreen
- Charts
- Diagrams
20 Part Number: 000015431 Rev 02 6/20
How to Read a Model Number
HEAD SECTIONS
ICE MACHINE SERIES
I Indigo
U Undercounter
KKoolaire
RFlake/Nugget
B Big shot
SS-series
IB Ice Beverage
C Countertop
REFRIGERANT TYPE
P R290 (propane)
F R404A (four)
T R410A (ten)
B R600A (butane)
E R134A (eight)
NOMINAL PRODUCTION @ 70/50
0300 produces ~300 #/day
0320 produces ~320 #/day
0350 produces ~350 #/day
etc. . .
Soo is stated in kg/day
CONDENSER TYPE
Aair cooled
Wwater cooled
N remote
(tradional)
C CVD (remote)
POWER CORD OPTION
Blank juncon box
Zcord without plug
B NEMA plug (USA)
F schuko plug (EU)
G 13A blade (GBR)
I oblique V blades
(AUS)
SPECIAL USE
Blankgeneral use
Qcoated condenser
H high pressure
Mmarine
Pcorreconal
Ttop air discharge
XLuminice/Sanitaon
L lever
V space maker
MARKET IDENTIFIER
Blank not market specific
SSaudi Arabia (GCC)
K Korea (KC)
C China (CCC)
D Germany (GS)
N Brazil (InMetro)
ICE TYPE
RRegular
DDice
Y Half-dice
F Flake
NNugget
G Gourmet
Blank for IB only
ELECTRICAL
CONFIGURATION
161 = 115/60/1
261 = 208-230/60/1
251 = 220-240/50/1 (S=230)
263 = 208-230/60/3
271 = 200/50-60/1
273 = 200/50-60/3
453 = 380-415/50/3
463 = 460/60/3
2= 22" wide cabinet
#= all other #s mean
producon value
I Y
T1 2 0 0 C –2 6 1 X
A
alternate compressor