Service Manual
Table Of Contents
- Safety Notices
- Definitions
- General Information
- Installation
- Stacking Two Ice Machines on a Single Storage Bin
- Location of Ice Machine
- Clearance Requirements
- Dual Evaporator Model Installation on a Manitowoc Bin
- Ice Machine on a Dispenser Installation
- Water Supply and Drains
- Lineset Applications
- QuietQube® Remote Condensing Unit
- Additional Refrigerant Charge For 51' to 100' Line Sets
- Maintenance
- Operation
- Menu Navigation
- Component Check Procedures
- Control Board, Display And Touchscreen
- Operating an ice machine without a Touchscreen
- Control Board Relay Test
- Programming A Replacement Control Board
- USB Flash Drive Specifications and Formatting
- Exporting Data to a Flash Drive
- Upgrading Firmware with a Flash Drive
- Main Fuse
- Bin Switch
- Water Level Control Circuitry
- Ice Thickness Probe (Initiates Harvest)
- Bin Level Probe
- Thermistors
- High Pressure Cutout (HPCO) Control
- Low Pressure Cutout (LPCO) Control
- Compressor Time Delay
- Fan Cycle Control
- Harvest Assist Air Pump
- Compressor Electrical Diagnostics
- Diagnosing Start Components
- Refrigeration Components
- Recovery/Evacuation/Charging Procedures QuietQube® Models
- System Contamination Clean-Up
- Total System Refrigerant Charge QuietQube® CVD Models
- Control Board, Display And Touchscreen
- Charts
- Diagrams
148 Part Number: 000015431 Rev 02 6/20
The initial numbers displayed are constantly changing
and are less than 3000.
With an initial reading of less than 300 and a tap test
reading of 3300 or higher indicates a good ice thickness
probe and control board.
The initial numbers displayed do not change or initial
numbers did not increase by 3000 during tap test.
• Verify the ice thickness probe connector is properly
plugged into the board and the ice thickness probe
wiring is correct. If the wiring is incorrect replace the
ice thickness probe.
J11 Connector On Control Board
Pin 1 (+) Red
Pin 2 (-) Black
Pin 3 Twisted Wire
10. Unplug the ice thickness probe and set a VOM to DC
voltage scale - Measure voltage across
Pin 1 (+) Red Wire and Pin 2 (-) Black Wire. Refer to
“Electronic Control Board” on page 200 for location.
A. Voltage measures 3.25 to 3.35 VDC = Replace ice
thickness probe.
B. Voltage does not measure 3.25 to 3.35 VDC =
Replace the control board.