User Manual

8 Part Number 000009036 8/13
Installation Section 2
HEIGHT REQUIREMENT
Either the base or the top of the AuCS® accessory must
be within 2" (5 cm) of the base of the ice machine. Do not
mount the AuCS® unit too high or too low.
,
Caution
The cleaner or sanitizer may siphon (or dispense
improperly) into the ice machine water trough if the
AuCS® unit is mounted too high or too low.
DISTANCE REQUIREMENT
The AuCS® unit must be mounted within 9 feet (2.7 m)
of the ice machine to accommodate the low voltage
communication wire and tubing. The tubing may be
shortened to accommodate a run of less than 9 feet (2.7 m).
,
Caution
Do not extend the length of the 9-foot (2.7 m) low
voltage communication wire or tubing. The correct
amount of solution will not dispense.
Box Base or Box Top
Must Be Within 2"
(5 cm) of Ice Machine
Base
2”
(5 cm)
Base of Ice
Machine
MOUNTING
Parts
Foam Tape
Bumper
1/2" PVC Conduit
Fitting
Hose Clamps
Locknut
Bracket
,
Caution
The AuCS® unit may be mounted to the bin or dispenser
only when permitted by local electrical codes.
Mounting to Bin or Dispenser
NOTE: The ice machines serviceability may be reduced
when the AuCS® unit is mounted to the bin or dispenser.
Wall mounting is recommended.
1. Set the mounting bracket over the bin top rail at
desired location.
2. Remove the backing from the foam adhesive tape.
Apply tape to mounting bracket, and along the entire
bin rail.
3. Align the AuCS® key slots with the mounting bracket
tabs. Verify the tabs are at the top of the key slots and
that the AuCS® unit is level.