Spec Sheet

2379G ©2012 Manitowoc 6/12 Continuing product improvement may necessitate change of specifications without notice.
iAuCS
®
Automatic Cleaning System
2110 South 26th Street
PO Box 1720
Manitowoc, WI 54221-1720 USA
Tel: 1.920.682.0161
Fax: 1.920.683.7589
www.manitowocice.com
2.00" (5 cm)
2.00" (5. cm)
Base Of
Ice Machine
NO!
(Too High)
NO!
(Too Low)
Box Base
Or Box Top
Must Be Within
2" Of Ice Machine
Base
NOTE: Box must also mount within reach of 9 foot (274 cm)
tubing and low voltage modular wire.
9' (2.73 m)
7.19" (18.30 cm)
3.43"
(8.71 cm)
12.12"
(30.78 cm)
iAuCS / iBAuCS
(External Mounting)
Compatibility: The iAuCS
model is for use with
all Indigo Series Cubers
i-300 to i-1800 and Indigo
QuietQube Models i-680C
to i-2170C. iBAuCS is for use
with all Indigo IB Models:
IB-0690C, IB-0890C and
IB-1090C.
Installation: The iAuCS is mounted on the wall near
the ice machine or on the bin with the included
bracket and hardware. iAuCS line voltage is
obtained from the ice machine. iBAuCS line voltage
requires external supply (unit comes pre-wired with
11' cord and NEMA 15-5P plug).
Setting Run Frequency: The frequency of cleanings
can be set through the menus of the the Indigo ice
machine.
Automatic Operation: Automatic cleaning initiated
by the AuCS system takes about 30 minutes
depending on the size of the machine. The water
in the trough is dumped and refilled at the start of
the cycle. The cleaner or sanitizer is dispensed from
the AuCS accessory and the water pump performs
a wash cycle followed by a series of rinse cycles.
Ice making automatically resumes when the AuCS
cycle is complete.