User Manual
Part Number 000009036 8/13 11
Section 2 Installation
3. Locate and remove either the membrane material or
the plug from the ice machine.
4. Apply food grade silicone and install Y connector
through the hole in the ice machine base. Connect
the clear vinyl tubing to one side of the Y branch. The
other side is for the plug removed in step 3 or the plug
provided with the AuCS.
Route tubing
to this area
Insert Y
connector
with tubing
Top View
Into Base of
Ice Machine
Connect
Tubing
Install plug
provided with
AuCS
or
plug removed
in Step 3
Y-Connector
5. Determine the amount of tubing required in the AuCS
control box and cut off the excess tubing.
6. Slide the tubing on the AuCSĀ® pump.
Slide the tubing
on the iAuCSĀ®