Specifications

106 Part Number STH025 02/12
Single Evaporator Remote Air-Cooled Condenser Models
Energized Parts Chart
Ice Making
Sequence of
Operation
Water
Pump
Harvest
Valve
(Left)
HPR
Valve
Harvest
Valve
(Right)
(When
Used)
Air
Pump
(When
Used)
Water
Inlet
Valve
Water
Dump
Valve
Contactor
Coil
Liquid Line
Solenoid
Compressor
Condenser
Fan Motor
Length
of Time
Initial Start-Up
1. Water Purge
On Off Off Off Off On Off Off Off
45 Seconds
2. Refrigeration
System Start-
up
Off On On On Off Off Off Off Off
5 Seconds
Off On On On Off Off On On On
5 Seconds
Freeze Sequence
3. Prechill
Off Off Off Off
May
Cycle
On/Off
during
pre-chill
Off On On On
Initial Start-Up is
60 Seconds
30 Seconds thereafter
4. Freeze
On Off Off Off
Cycles
Off
Then On
Two
more
times
Off On On On
Until Ice Contact
with Ice Thickness
Probe