Specifications
Part Number STH025 2/14 77
ICE BIN LEVEL SENSOR
Ice bin sensor is an optional accessory that allows the
ice level in the bin to be set to one of three different
levels. The bin level can be set seasonally to match
usage, which results in lower energy costs and fresher
ice.
1. From the Set-Up menu, use the Down arrow to
highlight Ice Bin Sensor.
2. Press the Checkmark. On this screen, you can
choose to set the ice level to Low, Medium or High
by highlighting your choice and pressing the
Checkmark. Selecting one will deselect the other.
When the check reflects your preference, use the
Down arrow to navigate to Exit and press the
Checkmark. The display will return to the Set-Up
menu.
USB SETUP
Refer to “Upgrading Firmware with a Flash Drive” and
“Exporting Data to a Flash Drive” for more information
on this setting. Flash drives must be correctly sized
and formatted - 2 gigabytes or smaller, Fat 32 file
system, 512 allocation units - Refer to
page 91 for full
specification and formatting details.
FACTORY DEFAULTS
The entire setup can be reset to factory defaults listed
on page
77.
1. From the Set-Up menu, use the Down arrow to
highlight Fact Default.
2. Press the Checkmark two times to reset the ice
machine. The display will return to the Set-Up
menu.