Specifications
218 Part Number STH025 2/14
REPLACING PRESSURE CONTROLS WITHOUT 
REMOVING REFRIGERANT CHARGE
This procedure reduces repair time and cost. Use it 
when any of the following components require 
replacement, and the refrigeration system is 
operational and leak-free.
• Fan cycle control (air cooled only)
• Water regulating valve (water cooled only)
• High pressure cut-out control
• Low Pressure cut-out control
• High side service valve
• Low side service valve
1. Disconnect power to the ice machine.
2. Follow all manufacturer’s instructions supplied 
with the pinch-off tool. Position the pinch-off tool 
around the tubing as far from the pressure control 
as feasible. (See the figure on next page.) Clamp 
down on the tubing until the pinch-off is complete.
3. Cut the tubing of the defective component with a 
small tubing cutter.
4. Solder the replacement component in place. 
Allow the solder joint to cool.
5. Remove the pinch-off tool.
6. Re-round the tubing. Position the flattened tubing 
in the proper hole in the pinch-off tool. Tighten the 
wing nuts until the block is tight and the tubing is 
rounded.
NOTE: The pressure controls will operate normally 
once the tubing is re-rounded. Tubing may not re-
round 100%.
Important
This is a required in-warranty repair procedure.
!
Warning
Do not unsolder a defective component. Cut it out of 
the system. Do not remove the pinch-off tool until the 
new component is securely in place.