Specifications

180 Part Number STH025 2/14
5.
Ohm Ice Thickness Probe
NOTE:
Verify meter leads are properly connected to
VOM with the red meter lead connected to positive &
the black meter lead connected to negative
Disconnect Ice Thickness Probe from control
board
Connect red meter lead to the red wire and the
black meter lead to the black wire - Normal
readings = 1.4 to 2.5 K's.
Reverse leads - Connect black meter lead to the
red wire, red meter lead to the black wire - Normal
readings = 1.2 to 1.5 K's.
6.
Check control board voltage
Set VOM to DC voltage scale - Check voltage
across the top and bottom pin - Normal readings =
3.25 to 3.35 VDC.
Pass Ohm values are within range - Check control board
voltage at the ice thickness probe connection.
Fail
Replace ice thickness probe.
Pass Control board voltage is normal
Fail
Replace control board