Specifications

Part Number STH025 2/14 163
Touch Pad Diagnostics
Follow the control board diagnostics to “Status
Passed”. Perform the following keystrokes on the
display.
Display reads Status Passed, press the right arrow
Display reads Pass Yes, press the right arrow
Display reads Key Pad Test, press the right arrow
4. Test the functionality of all buttons on the touch
pad.
NOTE: Pushing the power button will start and stop
the ice machine. Testing it last will allow the ice
machine to continue running a freeze cycle.
As you press the buttons the first letter of the
corresponding word will flash indicating the push
button is operating correctly or the corresponding
arrow or zero will flash.
Press the right arrow 5 times rapidly to exit.