Specifications
130 Part Number STH025 2/14
SINGLE EVAPORATOR, DUAL EXPANSION VALVE
SELF CONTAINED AIR, WATER & REMOTE CONDENSER
Operational Analysis 1 2 3 4
Ice Production
Air-Temperature Entering Condenser_____________
Water Temperature Entering Ice Machine_________
Published 24 hour ice production________________
Calculated (actual) ice production_______________
NOTE: The ice machine is operating properly if the ice fill patterns is normal and ice 
  production is within 10% of charted capacity.
Installation and Water 
System
All installation and water related problems must be corrected before proceeding with table.
Ice Formation Pattern
Top or 1 Side_________
Bottom or 1 Side_________
Ice formation is extremely 
thin on outlet of 
evaporator
-or-
No ice formation on one 
side or Top or Bottom of 
evaporator
Ice formation is 
extremely thin on outlet 
of one side or Top or 
Bottom of evaporator
-or-
No ice formation on 
entire evaporator
Ice formation normal
-or-
Ice formation is 
extremely thin at inlet of 
one side or Top or 
Bottom of evaporatorr
-or-
No ice formation on 
entire evaporator
Ice formation normal
-or-
No ice formation on 
entire evaporator