Specifications
128 Part Number STH025 2/14
Wait 5 minutes into the 
freeze cycle.
Compare temperatures of 
compressor discharge line 
and harvest valve inlet.
Reference “Harvest Valve 
Analysis” on page 148
The harvest valve inlet is 
Hot
-and-
approaches the 
temperature of a Hot 
compressor discharge 
line.
The harvest valve inlet 
is Cool enough to hold 
hand on
-and-
the compressor 
discharge line is Hot.
The harvest valve inlet 
is Cool enough to hold 
hand on
-and-
the compressor 
discharge line is Cool
enough to hold hand on.
The harvest valve inlet 
is Cool enough to hold 
hand on
-and-
the compressor 
discharge line is Hot.
Discharge Line 
Temperature
Record freeze cycle 
discharge line temperature at 
the end of the freeze cycle
T2 _________°F (°C)
Reference “Discharge Line 
Temperature Analysis” on 
page 150
Discharge line temp. 
150°F (65°C) 
or higher at the end of the 
freeze cycle
Discharge line temp. 
150°F (65°C)
or higher at the end of 
the freeze cycle
Discharge line temp. 
less than 
150°F (65°C) at the end 
of the freeze cycle
Discharge line temp. 
150°F (65°C) or higher 
at the end of the freeze 
cycle
SINGLE EVAPORATOR, SINGLE EXPANSION VALVE 
SELF CONTAINED AIR, WATER & REMOTE CONDENSER 
Operational Analysis 1 2 3 4