Spec Sheet

Welbilt reserves the right to make changes to the design or specications without prior notice.
www.manitowocice.com
6491 01/18
2110 South 26th Street
Manitowoc, WI 54220
Tel: 1.920.682.0161
Fax: 1.920.683.7589
QuietQube® iT1200C Remote Ice Cube Machine
Air-Cooled Ice Cube Machine with Patented CVD Technology®
Ice Machine Electric
115/60/1 standard.
Total Amps: 1.1
Max. fuse size: 15 amps
HACR-type circuit breakers can
be used in place of fuses.
iT1200C Ice Machine
iAuCS® Accessory
Automatic Cleaning
System purchased
as an option and
installed in the field.
Model
Ice
Shape
Ice Production
24 Hours
Power kWh/
100 lbs* @
90°/70°F
ENERGY
STAR®
70°Air/
50°F Water
90°Air/
70°F Water
IDT1200C dice
1,142 lbs. 975 lbs.
4.50
518 kgs. 442 kgs.
IYT1200C
half-
dice
1,146 lbs. 1000 lbs.
4.50
519 kgs. 454 kgs.
Water usage/100 lbs./45.4 kgs. of Ice
Potable Water: 19.9 gallons, 75.3 liters
Ice machine for use with ice storage bin or ice dispenser
and CVD condensing unit all ordered separately.
*kWh per 100 lbs. is total power of ice machine and
condensing unit. Ice machine is 1 ph only.
Condensing unit is 1 ph or 3 ph.
Remote Air-cooled Ice Machine
Specications
Operating Limits:
Ambient Temperature Range:
40˚ to 110˚F (4.4˚ to 43.3˚C)
Water Temperature Range:
40˚ to 90˚F (4.4˚ to 32.2˚C)
Water Pressure Ice Maker Water In:
Min. 20 psi (137.9 kPA)
Max. 80 psi (551.1 kPA)
25.75"
(65.4 cm)
24.13"
(61.3 cm)
34.00"
(86.4 cm)
A
C
C
B
B
Electrical
Entrance
(2) Options
Optional
Suction
& Liquid
Line
Connections
Suction
& Liquid
Line
Connections
A
B
C
Shipping Weight:
179 lbs. / 81 kgs.
A Electrical Entrance
(2) Options
Suction Refrigerant
Shut-o Valve
Liquid Refrigerant
Shut-o Valve
3/8" (0.95 cm) F.P.T.
Ice Making Water Inlet
1/2" (1.27 cm) F.P.T.
Ice Making Water Drain
B
C
D
E
B
C
A
D
E
29.50"
(74.9 cm)
30.00"
(76.20 cm)
24.50" (62.23 cm)
CDVT1200 Remote Condensing
Unit
Shipping Weight:
203 lbs. / 92 kgs.
Installation Information and Dimensions:
Maximum Line Length
—100' (30.5 m).*
Maximum Vertical Rise*
—35' (10.7 m) above ice machine.
Maximum Vertical Drop
—15' (4.5 m) below ice machine.
* A rise over 20' (6 m) requires S-Trap Kit K-00172 - ordered separately.
208-230/60/1 standard. 208-230/60/3. HACR-type
circuit breakers can be used in place of fuses.
Note: QuietQube ice machine power supply is wired
independent of CVD condensing unit.
Min. circuit ampacity:
14.8 1ph 9.3 3ph
Max. fuse size:
25 amps 1ph 15 amps 3ph
HACR-type circuit breakers can be used in place of fuses.
Operating Limits:
Ambient Temperature Range:
-20˚ to 130˚F (-29˚ to 54˚C)
BTU Per Hour:
16,200 (average) 19,100 (peak)
Compressor:
Nominal rating: 1.5 HP
Condensing Unit Electric
Model
Line Length Weight
ft. m. lbs. kgs.
RC-21 20 6 12 5
RC-31 30 9 20 9
RC-51 50 15 28 13