Specifications

Suction Line Oil Traps
0 to 20 feet (0 to 6.1 m) Rise: The ice machine head section
has one oil trap built in which allows for a maximum condenser
rise of 20 feet (6.1 m) without additional traps in the suction line.
21 to 35 feet (6.4 to 10.7 m) Rise: The suction line requires an
additional Oil Trap (ā€œSā€ type) to be installed. Install the trap as
close as possible to midpoint between the ice machine head
section and CVD condensing unit. See chart below for kits.
3/4 inch (19.1 mm)K00166
S1200C
S1470C
S1870C
S2070C
5/8 inch (15.9 mm) K00172
S600C
S850C
S1000C
Tubing Size
S-Trap Kit
Number
Model