Specifications

–197–
TOTAL SYSTEM REFRIGERANT CHARGE
NOTE: All ice machines on this list are charged using
R-404A refrigerant.
Total charge listed is for line set lengths up to 100 ft.
QDUAL Only:
For line set lengths over 50 ft., add 1 lb. of refrigerant
for each additional 10 ft. of tubing.
Important
This information is for reference only. Refer to the
ice machine serial number tag to verify the system
charge. Serial plate information overrides
information listed on this page.
Model
Condensing
Unit
Refrigerant
Charge
(lbs. / oz.)
Line Set
Length
Q0600C CVD675
11 lbs.
76 oz.
0-100 ft.
Q0800C CVD875
12 lbs.
192 oz.
0-100 ft.
11 lbs.
176 oz.
0-100 ft.
Q1000C
CVD1075
12 lbs.
192 oz.
0-100 ft.
SU1000C
SerVend
UC300
Dispenser
Q1400C
CVD1475
CVD1476
12.5 lbs.
192 oz.
0-100 ft.
QDUAL
CVD1875
CVD2075
19 lbs.
304 oz.
0-50 ft.