Service manual
Section 3 Maintenance
Part No. 80-1206-3 3-15
Water Level Probe
Q0600C/Q0800C/Q1000C/QDUALC
1. Loosen the screw that holds the water level probe in
place. The probe can easily be cleaned at this point
without proceeding to step 2.
2. If complete removal is required, disconnect the wire
lead from the control board inside the electrical
control box.
Water Level Probe Removal
Water Level Probe
IB0600C/IB0800C/IB1000C
1. Loosen the screw that holds the water level probe in
place. The probe can easily be cleaned at this point
without proceeding to step 2.
2. If complete removal is required, remove the top
cover, left and right side panels and control box
cover. Disconnect the wire lead from the control
board inside the electrical control box.
Ice Beverage Series Water Level Probe
!
Warning
Disconnect the electrical power to the ice machine
at the electrical disconnect before proceeding.
SCREW
WATER
LEVEL
PROBE
SV1621
WATER
TROUGH
WIRE
LEAD
ICE
MACHINE
SIDE
PANEL
!
Warning
Disconnect the electrical power to the ice machine
at the electrical disconnect before proceeding.
WATER
LEVEL
PROBE
SV3090
REMOVE
SCREW