Service manual

Maintenance Section 3
3-14
Part No. 80-1206-3
Water Pump
SU1000C/SerVend UC-300 Dispenser
1. Remove top and back access panels from the water
pump chimney.
2. Disconnect the water pump power cord.
3. Disconnect the hose from the pump outlet.
4. Loosen the screws securing the pump-mounting
bracket to the bulkhead.
5. Lift the pump and bracket assembly off the screws.
Water Distribution Tube
1. Remove the clamp from the vinyl water hose on the
right side of the distribution tube.
Water Distribution Tube Removal
2. Loosen the two thumbscrews which secure the
distribution tube.
SU1024YC - Loosen the three thumbscrews, which
secure the distribution tube.
3. Lift the right side of the distribution tube up, and then
rotate it backward and to the right until the left side
of the distribution tube disengages the thumbscrew.
4. Pull the vinyl hose off the distribution tube.
5. Disassemble for cleaning.
A. Twist both of the inner tube ends until the tabs
line up with the keyways.
B. Pull the inner tube ends outward.
!
Warning
Disconnect the electric power to the ice machine at
the electric service switch box and turn off the water
supply.
REMOVE
PANELS
SV2081
LOOSEN
SCREWS AND
LIFT PUMP
!
Warning
Disconnect the electrical power to the ice machine
at the electrical disconnect before proceeding.
!
Caution
Do not force this removal. Be sure the locating tab is
clear before rotating the distribution tube back.
SV1620
1. LIFT UP
2. SLIDE BACK
3. SLIDE TO RIGHT
DISTRIBUTION
TUBE
THUMBSCREW
THUMBSCREW
LOCATING
PIN
3
2
1