Service manual
Section 2 Installation Instructions
Part No. 80-1206-3 2-9
Electrical Requirements
QuietQube® Ice Machine Head Section
CVD® Condensing Unit
Ice Machine
Voltage
Phase
Cycle
Maximum Fuse/
Circuit Breaker
Total Amps
Q0600C IB0600C
Q0800C IB0800C
Q1000C IB1000C
SU1000C (UC-300 Dispenser)
Q1400C QDUALC
115/1/60
208-230/1/60
230/1/50
15 amp
15 amp
15 amp
1.1
0.6
0.6
Important
The QuietQube® Ice Machine Head Section and
CVD Condensing Unit are wired independently from
each other.
Condensing Unit
Voltage Phase
Cycle
Maximum Fuse/Circuit
Breaker
Minimum Circuit Amps
CVD0675
208-230/1/60
15 9.6
208-230/3/60
15 7.3
230/1/50
15 9.0
CVD0875
208-230/1/60 20 11.7
208-230/3/60
15 8.2
230/1/50
20 11.3
CVD1075
208-230/1/60 25 15.6
208-230/3/60
20 10.6
230/1/50
25 13.8
CVD1285
208-230/1/60 25 14.7
208-230/3/60
20 10.6
230/1/50
25 11.7
CVD1475
208-230/1/60
35 19.6
208-230/3/60
25 14.1
230/1/50
35 19.8
CVD1476
208-230/1/60 30 15.3
208-230/3/60 20 10.8
CVD1875
208-230/1/60 40 24.3
208-230/3/60 30 16.1
230/1/50 40 23.2
CVD2075
208-230/1/60 50 27.1
208-230/3/60 40 19.9
230/1/50 50 29.9