Specifications

Installation Instructions Section 2
2-12
Part Number 000001528
Refrigeration System Installation
USAGE WITH NON-MANITOWOC
CONDENSING UNITS
Manitowoc CVD® Condensing Units are specifically
designed for usage with a QuietQube® Ice Machine
Head Section. Standard condensing units and Non-
Manitowoc condensing units will not operate a
QuietQube® Ice Machine Head Section.
Factory Equipment Refrigeration Amounts
ICE MACHINE HEAD SECTION
Each ice machine head section ships from the factory
with a R-404A refrigerant charge appropriate for the
entire system operation. The serial tag on the ice
machine indicates the refrigerant charge. The refrigerant
charge is sufficient to operate the ice machine in
ambient temperatures between -20°F (-28.9°C) and
130°F (54.4°C)*. With line set lengths of up to 100 feet
(30.5 m).
*CVD1476 - 50°F to 110°F (10°C to 43°C)
CVD
® CONDENSING UNIT
Each condensing unit ships from the factory pressurized
with 50/50 nitrogen helium mixture that must be
removed during the installation process (approximately
20 psig).
REFRIGERATION LINE SETS/TRAP KIT
Refrigeration Rated Tubing and Trap Kits are shipped
capped with atmospheric pressure.
QuietQube®
Ice Machine
Remote Single
Circuit
Condenser
Line Set*
Q1400C
CVD1475
CVD1476
RC-20
RC-30
RC-50
Line Set Suction Line Liquid Line
Insulation
Thickness
RC 20/30/50
3/4 inch
(19.1 mm)
1/2 inch
(12.7 mm)
1/2”(13mm)
Suction Line
1/4” (7mm)
Liquid Line
!
Caution
The 60-month compressor warranty (including the
36-month labor replacement warranty) will not apply if
the Manitowoc Ice Machine and Manitowoc CVD
Condensing Unit are not installed according to
specifications. This warranty also will not apply if the
refrigeration system is modified with a condenser,
heat reclaim device, or other parts or assemblies not
manufactured by Manitowoc Ice, Inc.
!
Warning
The ice machine head section contains the refrigerant
charge. Installation and brazing of the line sets must be
performed by a properly trained and EPA certified
refrigeration technician aware of the dangers of dealing
with refrigerant charged equipment.
!
Caution
Never add more than nameplate charge to the
refrigeration system for any application.
!
Warning
Installation of a QuietQube® Condensing Unit may require
the use of special equipment for placement. Trained and
qualified personnel are required for proper rigging and
lifting.