Service Manual

Table Of Contents
60 Part Number 000015432 4/18
Power At
Terminals
#90 & #39?
Refer To Low and High
Pressure Cutout
Specifications.
NO
Nugget Contro
l Board
Light Energized?
NO
YES
Replace Control
Board
IMPORTANT
A 15-Minute Delay Initiates After The Problem Is
Corrected. This Delay Must Expire Before The Ice
Machine Will Start.
YES
YES
Disconnect HES #2
From Control Board.
Light Energizes?
NO
Replace HES #2
YES