Part Number 000015432 4/18 35
Sanitizing Procedure
Ice machine sanitizer is used to remove algae or slime. It is
not used to remove lime scale or other mineral deposits.
Refer to the “Cleaning Procedure” for removal of lime scale
or other mineral deposits.
NOTE: Sanitizing must be performed on adjacent surface
areas not contacted by the water distribution system.
Always perform Component Disassembly for Cleaning/
Sanitizing procedure and a Cleaning Procedure before
sanitizing the ice machine.
Step 1 Turn off the water supply to the ice machine.
Step 2 Place ICE/OFF/CLEAN toggle switch in the
CLEAN position. The dump valve will open and drain the
water from the evaporator and reservoir.
Step 3 Wait approximately 30 seconds (or until the
evaporator is drained) and place the toggle switch in the
OFF position.
Step 4 Refer to chart and premix the correct solution
of sanitizer and cool water for your model ice machine.
Model Amount of Sanitizer
Part Number
9405653
Amount of Water
CNF201 CNF202 2 ounces (60 ml) 3 gallons (11.4L)
Step 5 Remove the top cover from the ice chute and
pour the sanitizer/water solution into the evaporator. Add
the entire amount of premixed solution (excess solution
will exit through the overflow tube in the water reservoir).
Step 6 Replace the ice chute cover and allow the ice
machine to stand for 30 minutes.
Step 7 Turn on the water supply to the ice machine.
Step 8 Move the toggle switch to the ICE position. The
compressor will energize after the 15 minute delay and
produce ice with the sanitizing solution.