DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice
machine and storage bin:
Drain lines must have a 1.5 in. drop per 5 ft. of run
(2.5 cm per meter), and must not create traps.
The floor drain must be large enough to accommodate
drainage from all drains.
Run separate bin drain line. Insulate to prevent
condensation.
Vent the bin drain to the atmosphere.
Drains must have a union or other suitable means to
allow a place of disconnection from the ice machine
when servicing is required.