Service Manual
Table Of Contents
- General Information
- Model Numbers
- Installation
- Maintenance
- Troubleshooting
- Component Check Procedures
- Electrical Components
- Main Fuse
- ICE/OFF/CLEAN Toggle Switch
- Float Switch
- Ice Damper and Hall Effect Switches
- Selector Switch
- Dispense Lever Activated
- Touchless Sensor Activated
- Dispense Switch
- Touchless Sensor
- High Pressure Cutout Control
- Fan Cycle Control
- Low Pressure Cutout (LPCO) Control
- Compressor Electrical Diagnostics
- Diagnosing Start Components
- Refrigerant Recovery/Evacuation
- System Contamination Clean-Up
- Electrical Components
- Component Specifications
- Charts
- Diagrams
30 Part Number 000015432 4/18
Changing toggle switch position during clean cycle:
1. Less than 60 seconds into Clean cycle - The Clean
cycle will end when the toggle switch is moved to the
OFF position.
2. More than 60 seconds into Clean cycle - The ice
machine will complete the clean cycle. Toggle switch
position will determine the next cycle after the Clean
cycle is completed.
• CLEAN POSITION - The ice machine will wait for a
change in toggle switch position.
• OFF POSITION - The ice machine will wait for a
change in toggle switch position.
• ICE POSITION - The ice machine will start making
ice automatically.
3. To abort the clean cycle move the toggle switch from
CLEAN to OFF to CLEAN and back to OFF within a 15
second time period.
Manitowoc recommends disassembling, cleaning and
sanitizing the ice machine and dispenser every six months.