Specifications
Ice Machine Operation Section 3
3-2
Changing Switch Position During Automatic Operation
If the toggle switch is moved to OFF prior to the
pump dispensing (less than 45 seconds into the cycle)
then switched to:
ICE
A normal ice-making mode begins.
CLEAN
A manual clean cycle begins.
(See “Manual Start Operation,” page 3-1.)
If the toggle switch is moved to OFF after the pump
dispenses (more than 45 seconds into the cycle, but
before rinse cycles begin) then switched to:
ICE
The “clean” portion of the cycle begins.
After completion of the 10-minute
“Clean” and 6 rinse cycles, the counter
resets and a normal ice-making mode
begins.
CLEAN
A manual clean cycle begins.
(See “Manual Start Operation,” page 3-1.)
After completion of the 10-minute
“Clean” and 6 rinse cycles, the counter
resets and the ice machine awaits a
change in the toggle switch position.
If the toggle switch is moved to OFF after the 6 rinse
cycles have begun and then switched from off to:
ICE
The rinse portion of the cycle restarts and
continues.
After completion of the 6 additional rinse
cycles, the counter resets and a normal
ice-making mode begins.
CLEAN
A manual clean cycle begins.
(See “Manual Start Operation,” page 3-1.)
After completion of the 10-minute
“Clean” and 6 rinse cycles, the counter
resets and the ice machine awaits a
change in the toggle switch position.