Specifications

Installation Instructions Section 2
6
Part Number 000007647 06/11
AuCS®-SO Installation
LOCATION / MOUNTING
The location selected for the AuCS®-SO accessory
must meet the following criteria. If any of these criteria
are not met, select another location.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 40°F (4°C), but
must not exceed 110°F (43°C).
The location must not be near heat-generating
equipment or in direct sunlight.
HEIGHT REQUIREMENT
Either the base or the top of the AuCS®-SO accessory
must be within 2" (5 cm) of the base of the ice machine.
Do not mount the AuCS®-SO too high or too low.
DISTANCE REQUIREMENT
The AuCS®-SO must be mounted within 9 feet (2.7 m)
of the ice machine to accommodate the low voltage
communication wire and tubing. The tubing may be
shortened to accommodate a run of less than 9 feet
(2.7 m).
!
Warning
All wiring must conform to local, state and national
codes.
!
Warning
The ice machine and AuCS®-SO must be grounded
in accordance with national and local electrical
codes.
Important
Observe correct polarity of incoming line voltage.
!
Caution
The AuCS® accessory must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty. See
“Removal from Service/Winterization”.
!
Caution
The cleaner or sanitizer may siphon (or dispense
improperly) into the ice machine water trough if the
AuCS®-SO is mounted too high or too low.
!
Caution
Do not extend the length of the 9-foot (2.7 m) low
voltage communication wire or tubing. The correct
amount of solution will not dispense.
BASE OF ICE
MACHINE
2"
(5 cm)
BOX BASE OR BOX TOP
MUST BE WITHIN 2"
(5 cm) OF ICE MACHINE
BASE