Specifications
Section 2 Installation Instructions
Part Number 000007647 06/11 5
Top View
Y-Connector
7. Route line voltage wires through control box line
voltage heyco fitting. Connect line voltage wires to
incoming power supply of contactor and ground
screw.
NOTE: On S QuietQube Ice Machines the power
connection is made at the incoming power supply
(L1 and L2). Cut-off yellow terminal (L2) and purple
terminal (L1) on AuCS harness. Strip insulation back
1/2" (13 mm) and connect.
8. Route modular wire through control box low voltage
heyco fitting. Do not route with line voltage wiring,
erratic operation could result. Connect modular wire
to control board.
9. Remove screw from ice machine base.
10. Remove cover from AuCS®-SI.
11. Slide the AuCS®-SI partially into ice machine below
control box.
A. Connect vinyl tubing to AuCS®-SI pump outlet.
B. Route communication wire (4 prong plug)
through left heyco fitting and attach to
AuCS®-SI control board.
12. Use screw removed in step 6 to secure AuCS®-SI to
the ice machine.
Route tubing
to this area
Insert Y
connector
with tubing
Connect
tubing
Install plug
removed in
Step 5
Into Base of
Ice Machine
Line Voltage
Heyco
Fittings
Connect to
incoming power
supply of contactor
observing proper
polarity for 115V
Connect
ground wire
to ground
screw
Low Voltage
Heyco Fitting
Control Board
Connection
SCREW
LOCATION
12
11B
11A