Specifications

Operation Section 3
12
Part Number 000007647 06/11
5. Reinstall left panel.
Changing the Solution Type
Use the following procedure to flush the system prior to
changing from Cleaner to Sanitizer or from Sanitizer to
Cleaner.
1. Remove the bottle of Cleaner or Sanitizer from the
AuCS®. Flush the bottle thoroughly then fill with
water.
2. Repeat the following until the water bottle is empty
(approximately 8 times):
A. Move the ice machine toggle switch to CLEAN.
B. The water pump and dump valve will turn on.
The dump valve will shut off after approximately
45 seconds.
C. The control waits until the water contacts the
water level probe then energizes the AuCS®
pump (22" or 30" ice machines - 30 seconds,
48" ice machines - 60 seconds).
D. Move the switch to OFF after step C is
completed.
3. Install a new bottle of cleaner or sanitizer solution.
Unscrew cap and remove bottle
Remove cap and foil seal from
new bottle and install
!
Caution
Wear rubber gloves and safety goggles (and/or face
shield) when handling Cleaner and Sanitizer.
!
Caution
Do not mix Cleaner and Sanitizer solutions together.
It is a violation of Federal law to use these solutions
in a manner inconsistent with their labeling.
!
Warning
Do not use 1 gallon bottles of Cleaner or Sanitizer
on the AuCS® accessory.