Specifications

Maintenance Section 4
38
Part Number 000007345 2/12
Preventative Maintenance Cleaning
Procedure
This procedure cleans all components in the water flow
path, and is used to clean the ice machine between the
bi-yearly cleaning/sanitizing procedure.
Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
NOTE: It is not required to remove the ice from the bin/
dispenser during this cleaning procedure.
Step 1 Ice must not be on the evaporator during the
clean/sanitize cycle. Follow one of the methods below:
Press the power switch at the end of a harvest cycle
after ice falls from the evaporator(s).
Press the power switch and allow the ice to melt.
Step 2 Open the front door to access the evaporator.
Step 3 Press the clean switch. Water will flow through
the water dump valve and down the drain. Wait until the
water trough refills and the display indicates add solution
(approximately 1 minute), then add the proper amount of
ice machine cleaner.
Step 4 Close and secure the front door. The ice
machine will automatically start ice making after the
clean cycle is complete (approximately 24 minutes).
Door Removal
1. Use a phillips screwdriver to loosen the two screws
securing the door. Do not remove they are retained
to prevent loss.
2. Open left front door to 90 degrees. .
Door Removal
3. Support with right hand, depress top pin, tilt top of
door forward and lift out of bottom pin to remove.
!
Caution
Never use anything to force ice from the evaporator.
Damage may result.
Model Amount of Cleaner
I0300/I0320/I0520 3 ounces (90 ml)
I0450/I0500/I0600
I0850/I1000/I1200
5 ounces (150 ml)
I1400/I1600/I1800 9 ounces (265 ml)
I3300 16 ounces (475 ml)
1