Section 2 Installation
n
Warning
Cutting the countertop may decrease its strength.
Counter must be braced to support the dispenser
countertop weight plus ice storage capacity and weight
of ice machine, if applicable.
Location
The location selected for the beverage dispenser must meet
the following criteria. If any of these criteria are not met,
select another location.
• Dispenser is only to be installed in locations where it can
be overseen by trained personnel.
• The air temperature must be at least 50°F (10°C), but
must not exceed 95°F (35°C).
• The location must not be near heat-generating
equipment or in direct sunlight and must be protected
from weather.
• The countertop must be level. Verify that the countertop
can support the weight of the dispenser, or the
dispenser/ice machine combination plus the weight of
the stored ice.
• Water lines, drains and power outlet must be within 6'
(1.8 m) of location.
n
Warning
Carbon Dioxide (CO
2
) displaces oxygen. Exposure to a
high concentration of CO
2
gas causes tremors, which
are followed rapidly by loss of consciousness and
suffocation. If a CO
2
gas leak is suspected, particularly
in a small area, immediately ventilate the area before
repairing the leak. CO
2
lines and pumps must not be
installed in an enclosed space. An enclosed space can
be a cooler or small room or closet. This may include
convenience stores with glass door self serve coolers. If
you suspect CO
2
may build up in an area, venting of the
B-I-B pumps and/or CO
2
monitors must be utilized.
n
Warning
Carbon Dioxide (CO
2
)
ALWAYS
• Connect the CO
2
or Gas Cylinder to a reducing valve.
• Secure cylinder upright during use.
• Keep cylinder away from heat.
• Ventilate area after CO
2
leakage.
NEVER
• Try to connect cylinder directly to product container.
• Interconnect soft drinks, CO
2
or gas cylinder
equipment with other equipment.
• Drop or throw cylinders.
• Try to unscrew fittings from containers.
This information should be displayed in a position
adjacent to the CO
2
supply cylinders at all times.
Ways Equipment Should Not be Used
This equipment should be used only in accordance with the
instructions. This equipment is designed to be installed on a
counter, dispense ice, and/or carbonate, chill mains potable
water, and chill soft drink syrup. It should not be used for
any other purpose.
• Do not use the product coils to chill other products than
those stated above.
• Do not operate the equipment in a wet environment.
Any spillage must be wiped dry immediately.
• The unit should not be installed in small enclosed
spaces such as cupboards or pantries, where fresh air
flow is restricted and service may not be able to access.
• Keep the unit free from excessive heat and cold.
• Misuse or use of the equipment for any other purpose
than those identified above will invalidate any warranty
and may constitute a danger to yourself and others.