User Manual
Part Number 020003996 3/15 23
Section 2 Installation
Important
If incoming water pressure is under 40 psi (2.76 BAR,
275,790 Pa), a water booster is recommended. If
incoming water pressure is over 55 psi (3.79 BAR 379,
211 Pa), a water regulating valve is required.
ADA KEY PADS
These instructions are for installations with this option.
1. Remove power from the unit.
Merchandiser Removal
2. Loosen the two knurled fasteners located in the top of
the merchandiser that hold the merchandiser in place.
3. Remove the merchandiser by lifting up and tilting
forward.
Splash Panel Removal
4. Remove the splash panel from the unit by removing
the two (2) phillips head screws holding it in place.
ADA Wiring
5. Route the ADA ribbon cable under the drain pan.
ADA Ribbon
Cable
Drain
Pan
6. Continue routing the ADA cable behind the valve
mount cap on the left hand side of the unit.
ADA
Harness
ADA Box
Ribbon
Connector
ADA Box
Ribbon
Cable
7. Connect the ADA ribbon cable to the ADA wire harness
located to the left of the ice chute and held to the foam
front by a wire clip.
ADA Box
Ribbon
Cable
ADA
Harness
ADA Wire
Harness Clip
8. Neatly tuck in and take up any slack remaining in the
ADA ribbon cable so it will not be in the way of any
moving parts or panels when they are placed back on
the unit.
Drain Pan & ADA Touch Pad Box
9. Attach the drain pan to the unit.
10. Center the ADA Key Pad Box with the unit in front of
the drain pan and secure into place.
Connected
ADA Cables
Drain
Pan
ADA Box
Important
If mounting the ADA Box directly in front of the drain
pan on the countertop, leave a minimum of 1" (2.5 cm)
space between the bottom edge of the drain pan and
the ADA Box to allow space for drain pan removal.