User Manual

20 Part Number 020003996 3/15
Installation Section 2
CO
2
Supply
ROUTING INTERNAL CARB TANK PURGE TUBE
Some models are equipped with an internal carbonation
tank. These models require that the purge/pressure relief
tubing be routed to a drain.
1. Remove the splash panel.
2. Uncoil tubing and route between the front of the
dispenser and the drain pan.
Drain Pan
SV-200 & 250
3. Depending on drain location, route the tubing through
the tubing bundle cutout or out the back of the
dispenser.
Rear of Unit
To Drain
4. Verify the tubing is not kinked and then secure tubing
to maintain a minimum 1" (2.5 cm) air gap at the drain.
Follow any applicable local or national codes.
Drains
S/SV/SVI/NGF Series dispensers drain through a double connection to the drain pan.
Drainage Through Bottom Drainage Through Back Rear View
Rear Access for Drain Hose and
Beverage Lines
Radiator Clamp
Flexible Tubing
90° Elbow Fitting
Radiator Clamp
Flexible Tubing
Straight Fitting