Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
108 Part Number STH14 9/10
S9 (Syrup 9) on Valve 15 is the only syrup that does not correspond to
the side it is mounted to. Both visually and functionally all other valves,
touch pads, and dispense points correspond with the board on the
same side to which they are attached.
GENERAL BRIXING PROCESS
1. With the corresponding control board set to brix
mode and displaying a 2 you may brix a beverage
nozzle (NI, N3, N4, or N6). If brixing a syrup, the
use of a funnel between the cup and nozzle may
aid in the capture of the syrup. (See nozzle order
below.)
S5
S4
F2
F1
S9
S8
F3
F4
C1 S1 S2 S3 S6 S7 C2 NC2 C3 NC3 S11 S10 S15 S14 C4 S16
F6
F5
F7
F8
S13
S12
S1
S3
S2 S4
S5
S7
S6 S8
F1
F2
F4
F3
N1 N3
N2
S1, S3,
S2, S4
C1
S5, S7,
S6, S8,
C2, NC2
S12 S10
S11 S9
S16 S14
S15 S13
F5
F6 F8
F7
N4 N6
N5
S9, S11,
S10, S12,
C3, NC3
S13, S15,
S14, S16,
C4
F1, F3,
F2, F4
F5, F7,
F6, F8
= WATER
= SYRUP
= FLAVOR
SHOT
LEFT SIDE
CONTROL BOARD
RIGHT SIDE
CONTROL BOARD
Valve Controls - C1, C2, NC2,
S1-S8, F1-F4
Valve Controls - C3, C4, NC3,
S9-S16, F5-F8
Valve 14 Valve 15
Valve 13 Valve 12
Valve 8 Valve 9 Valve 10 Valve 11
Valve 4 Valve 3 Valve 2 Valve 1
Valve 6 Val ve 5
Valve 7
STH14.book Page 108 Thursday, September 23, 2010 3:35 PM