Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
Part Number STH14 9/10 107
4. Locate the control board that corresponds with
the valve(s) and/or dispense point you want to
brix.
5. Press the program button and hold for 3 seconds
or until the LED displays 1. Press the program
button again until 2 is displayed on the control
board LED display.
NOTE: Programming one board at a time will make it
easier for you to identify the corresponding valves and
dispense points. See Flav’R-Pic External
Programming in this manual for more detail on all
programming modes.
6. With a board in Mode 2 you can now brix any
water or syrup valve that corresponds to the
board. Use the chart above to identify the valves
and which board they correspond to. See the
illustration that follows for more assistance.
Brixing information can also be found on the right
hand side of the control board cover label. By
using this label in combination with the plumbing
label you will be able to identify each valve, water,
and/or syrup combination.
Left Board Right Board
Dispense Type and
Valve Number
C1 - Valve 8 C3 - Valve 4
C2 - Valve 11 C4 - Valve 1
NC2 - Valve 11 NC3 - Valve 4
S1 - Valve 8 S9 - Valve 15
S2 - Valve 9 S10 - Valve 3
S3 - Valve 9 S11 - Valve 3
S4 - Valve 14 S12 - Valve 7
S5 - Valve 14 S13 - Valve 7
S6 - Valve 10 S14 - Valve 2
S7 - Valve 10 S15 - Valve 2
S8 - Valve 15 S16 - Valve 1
F1 - Valve 13 F5 - Valve 6
F2 - Valve 13 F6 - Valve 6
F3 - Valve 12 F7 - Valve 5
F4 - Valve 12 F8 - Valve 5
C = Carb NC = Non-Carb S = Syrup F = Flavor Shot