Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
Part Number STH14 9/10 95
CHANGING NUMBER OF ACTIVE FLAVORS
To line up flavors with valves, note that valve outlets
number from left to right 1…2…3…4. Touch pad flavor
tab is numbered as shown below. Connect vinyl tube
from outlet 1 and dispense with flavor tab 1, etc.
The current Flavor Magic control board is set up in the
4 flavor default mode. This mode will handle all
dispensing situations whether 3 or 4 flavors are used.
Some early boards were set up as default in the 3
flavor mode. If the customer desires to add another
flavor for a total of 4, proceed as follows:
1. Power down the circuit board by disconnecting
the 24 volt connector in the lower left hand side of
the board. “24VAC” is imprinted on the board next
to the pin connection.
2. Wait a minimum of 10 seconds.
3. Power up the board by connecting the 24 volt
connector.
4. IMMEDIATELY (within 5 seconds) press and hold
the “PROG” button down.
5. After a few seconds, the number “4” will appear
on the display.
6. Release the “PROG” button. The board will cycle
the display from “Pro” to
“4……3……2……1……0” and then to “- - - -”.
7. The circuit board is now enabled to dispense the
4th flavor. The 4th flavor button is the top middle
button.
1
4
3
2
STH14.book Page 95 Thursday, September 23, 2010 3:35 PM