Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
Part Number STH14 9/10 39
Setting Pressures
PRE-MIX PRESSURES
Normal pre-mix pressure regulators must be set at
60 psi (4.14 bar). Diet pre-mix pressure regulators
must be set at 40 psi (2.76 bar). If you are
experiencing high foaming, decreasing the pressures
may correct the problem. Spitting and popping usually
requires slightly increasing the pressures. Pre-mix
beverage valve pressures vary by type and
manufacturer. Please consult the manufacturer of the
valves you are using for specific instructions regarding
operation of the valve.
COLD CARB AND AMBIENT SYSTEM PRESSURES
1. Incoming tap water — must be at a minimum
dynamic pressure of 40 psi (2.76 bar) and
maximum static pressure of 65 psi (4.48 bar)
(measured at inlet to pump).
2. B-I-B pressure gauge must be set for a minimum
of 60 psi (4.14 bar) or according to your line run.
3. Carbonator Pressure gauge (Use Preset
Regulator):
- Cold Carbonation set for 75 psi (5.17 bar).
- Ambient systems must be set at 90 psi to
105 psi (6.20 bar to 7.24 bar).
Important
If incoming water pressure is under 40 psi
(2.76 bar), a water booster is recommended. If
incoming water pressure is over 65 psi (4.48 bar),
a water regulating valve is required.