Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
Part Number STH14 9/10 177
S/SV150 6 Valve Diagram
S/SV175 8 Valve Diagram
3
INTERNAL CARBONATOR TANK
PLUMBING: 2-1-1-2 MANIFOLDING
*OPTIONAL*
VARIETY VALVE ON #3
1 – WATER
(THRU COLDPLATE)
2 – SYRUP
(AMBIENT)
3 – SYRUP
(AMBIENT)
4 – SYRUP
(THRU COLDPLATE)
VALVES “SYRUP LINES NOT SHOWN”
PRE-CHILL OUT TO CARBONATOR
654321
2
4
2112
1,2 3 4 5,6
VALVES
CIRCUITS
CO
2
Manifold: Change to carbonated or non-carbonated
water.
1. Rotate plunger 180° using a 5/32" Hex Key wrench.
2. Pull plunger up to get non-carbonated water.
3. Push plunger down to get carbonated water.
4. Turn plunger back 180° to lock.
5. Port 5 is not used.
Plain Water
(Plain Water Supply)
CARBONATOR OUT TO POST-CHILL
Plain Water
(From
Pump to
Carbonator)
#1 #2 #3 #4 #5 #6
Syrup Lines
COLD PLATE
*EXTERNALLY CARBONATED UNITS: CARBONATOR IS REPLACED BY BY-PASS TUBE
FOR ASSISTANCE CALL (812) 246-7000
1
3
INTERNAL CARBONATOR TANK
(Optional)
PLUMBING: 3-1-1-1-2 MANIFOLDING
*OPTIONAL*
VARIETY VALVE ON #4
1 – WATER
(THRU COLDPLATE)
2 – SYRUP
(AMBIENT)
3 – SYRUP
(AMBIENT)
4 – SYRUP
(THRU COLDPLATE)
VALVES “SYRUP LINES NOT SHOWN”
PRE-CHILL OUT TO CARBONATOR
654321
2
4
2111
7,8 6 7 4
VALVES
CIRCUITS
CO
2
Manifold: Change to carbonated or non-carbonated water.
1. Rotate plunger 180° using a 5/32" Hex Key wrench.
2. Pull plunger up to get non-carbonated water.
3. Push plunger down to get carbonated water.
4. Turn plunger back 180° to lock.
5. Port 5 is not used.
Plain Water
(Plain Water Supply)
CARBONATOR OUT TO POST-CHILL
Plain Water
(From
Pump to
Carbonator)
#1 #2 #3 #4 #5 #6
Syrup Lines
COLD PLATE
*EXTERNALLY CARBONATED UNITS: CARBONATOR IS REPLACED BY BY-PASS TUBE
FOR ASSISTANCE CALL (812) 246-7000