Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
174 Part Number STH14 9/10
MDH-302 12 Valve Plumbing
MDH-302 Left Hand Side
Servend Recommended Plumbing
Post-chill
Flex Manifold
Pre-chill
2-1-1-2 Flex
Left to Right
For Assistance
(812) 246-7000
Note: Syrup lines not shown.
Inlet Lines
Note: Internally carbonated units - From carbonator pump to carbonator located on unit
Externally carbonated units - From external carbonator to manifold.
Carb Water
(A) (See Note)
Plain Water
(C)
#7 Syrup
#8 Syrup
#9 Syrup
#10 Syrup
#11 Syrup
#12 Syrup
MDH-302 Right Hand Side
Servend Recommended Plumbing
Post-chill
Flex Manifold
Pre-chill
2-1-1-2 Flex
Left to Right
Note: Syrup lines not shown.
Inlet Lines
Note: Internally carbonated units - From carbonator pump to carbonator located on unit
Externally carbonated units - From external carbonator to manifold.
Carb Water
(A) (See Note)
Plain Water
(C)
#6 Syrup
#5 Syrup
#4 Syrup
#3 Syrup
#2 Syrup
#1 Syrup
Internally Carbonated Units
A = Plain Water to Carbonator
B = Carb Water from Internal
B = Carbonator to Flex Manifold
C = Plain Water to Flex Manifold
Externally Carbonated Units
A = Plain Water to Remote Carbonator
A = Pump Deck Tank (In)
B = Carb Water from Remote Carbonator
B = Pump Deck Tank (Out)
C = Plain Water to Flex-Manifold
*Externally Carbonated Units*
Carbonator Tank is Replace by
By-pass Tube
Internal
Carbonator
Tank
In
Out
A
B
C
A
A
C