Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
Part Number STH14 9/10 165
DI/DIL-2323 6 Valve Post-mix Plumbing
SERVEND RECOMMENDED PLUMBING: DI-1522 PREMIX
1-1-1-1-2 Flex
Left to Right
For 6 Valve Units
For Assistance Call
812-246-7000
3/4" NPT
Drainpan
Drain
3/4" NPT
Coldplate
Drain
Bottom View
Relief Valve
Items within bold boxes are
for internal carbonation only.
*Plugged*
*Plugged*
Water #6
#6 Syrup
Water #5
#5 Syrup
Water #4
#4 Syrup
Water #3
#3 Syrup
CO
2
to
Carbonabor
Carbonabor
Internally
carbonated
units only
Water #2
#2 Syrup
*Plugged*
*Plugged*
Water #1
#1 Syrup
CO
2
IN
#6 Syrup
#5 Syrup
#4 Syrup
#3 Syrup
#2 Syrup
#1 Syrup
Water #6
Water #5
Water #4
Water #3
Water #1 & #2
A
B
Ambient Carbonation
A = Carbonated water
B = Plain water
Internal Carbonation
A = Plain water to carbonator from pump
B = Plain water (40-55 psi) to manifold
C = Carbonated water from carbonator to manifold
Operation:
Manifold to Change to Carbonated
or Non-carbonated Water
1. Rotate plunger 180° using a 5/32"
1. allen wrench.
2. Pull plunger up to get non-carb water.
2. Push plunger down to get carb. water.
3. Turn plunger back 180° to lock.
Valves
5,6 4 3 1,2
Carb Water
Plain Water
Valve Locations
STH14.book Page 165 Thursday, September 23, 2010 3:35 PM