Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
140 Part Number STH14 9/10
Minimum Circuit Amperage Chart
NOTE: For FlexTower applications — A dedicated
120 VAC, 15 ampere circuit is required to provide
power to the power supply’s transformer with an
output of 24 VAC for the electric valves, 120 VAC,
8 ampere circuit, and to power a cold water
recirculation pump. The power supply has a 120 VAC
outlet to provide power for the cold water recirculation
pump.
Important
Due to continuous improvements, this information
is for reference only. Please refer to the
dispenser serial number tag to verify electrical
data. Serial tag information overrides information
listed on this page.
Dispenser Voltage/Cycle
Minimum
Circuit Amps
CEV-30, CEV-40 120/60 8.2
208-230/60,
220-240/50Hz
DI-1522, CT-6 120/60 2.4
220/50
DI/DIL2323, CT-8 120/60 3.2
220/50
Flavor Magic 24VAC, powered
by existing valve
transformer on
dispenser
0.5
FlexTower 120/60 2.5
FRP-250 120/60 3.0
MDH-302, MDH-402 120/60 3.5
MDH-302SCI,
MDH-402SCI
120/60 5.4
S-150, S-200, S-250,
SV-150, SV-175,
SV-200, SV-250,
SV-150i, SV-175i,
SV-200i, SV-250i,
SV-250QD, NGF-250,
NGF-250QD
115/60 2.8
220/50, 220/60,
240/50, 240/60
1.5
220-240/50 5
(with carb
deck)