User Manual

40 Part Number 020003996 3/15
Maintenance Section 4
Sanitizing
BEVERAGE SYSTEM CLEANING
n
Warning
Flush sanitizing solution from syrup system.
Residual sanitizing solution left in system could create a
health hazard.
n
Warning
When using cleaning fluids or chemicals, rubber gloves
and eye protection must be worn.
Sanitize the beverage system at initial start-up as well
as regularly scheduled cleaning. The drain pan must be
in place under soda valves, to carry away detergent and
sanitizing agents that will be flushed through valves.
BAGINBOX SYSTEM SANITATION
The procedure below is for the sanitation of one syrup
circuit at a time. Repeat to sanitize additional circuits.
You will need the following items to clean and sanitize the
Bag-in-Box (BIB) beverage system:
Three (3) clean buckets
Plastic brush or soft cloth
Mild detergent
Unscented bleach (5% Na CL O) or commercial sanitizer
Bag-In-Box bag connector
1. Prepare the following in the buckets:
Bucket 1 — warm to hot tap water for rinsing.
Bucket 2 — mild detergent and warm to hot
water.
Bucket 3 — mix a solution of unscented bleach
(5% Na CL O) or commercial sanitizer and warm
to hot water. Mixture must supply 100 PPM
available chlorine (1/4 oz. [7.5 ml] bleach to
1gallon [7.6 liters] water).
2. Disconnect the “syrup-line side” of the BIB connector.
3. Rinse connector with warm tap water.
4. Connect syrup connector to BIB connector and
immerse both into Bucket 1. A “bag-side” connector
can be created by cutting the connector from an empty
disposable syrup bag.