User Manual

Part Number 020003996 3/15 29
Section 3 Operation
When this jumper is in place, the LED will blink at one-
second intervals. This is the run mode.
When the jumper is open, the LED will flash every 0.4
second. This is the test mode and the timer will cycle every
55 seconds in test mode. If the timer is left in test mode, it
will automatically reset to run mode.
4
NO
1
COM
5
NC
6
3
2
RED
Agitation Timer
Important
Quickdraw ice & beverage dispensers do not have an
agitation timer and need to be left in Auto Mode at
night so periodic ice agitation takes place.
Operation Checks and Adjustments
ROCKING CHUTE ICE DELIVERY SWITCH ADJUSTMENT
To properly adjust the switch, first unplug the power cord to
the unit, then remove the merchandiser. This will give you
access to the ice delivery switch located on the left side of
the rocking chute.
Ice
Delivery
Switch
Door
Door Lock
Door Stops
Begin by observing the chute by slowly pushing against
the rocking chute. When the ice delivery switch clicks,
measure the distance from the door stops on the rocking
chute bracket to the door. The distance between the two
must be no more than 1/4" (0.64 cm), but no less than 1/16"
(0.16cm).
Door
Door Lock
Door Stops
1/16"
to
1/4"
The left side of the rocking chute has a tab that pushes
up on the ice delivery switch. To adjust it, use needle nose
pliers and bend the arm of the switch up or down in order
to change the point where the tab makes contact with the
switch arm.
Switch Arm
Tab