User Manual

12 Part Number 020003996 3/15
Installation Section 2
Electrical
GENERAL
n
Warning
All wiring must conform to local, state and national
codes. Changes to the mains cable and plug can only be
made by a qualified electrician.
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select the
wire size of the electrical supply. (Minimum circuit ampacity
is not the beverage/ice machines running amp load.)
The wire size (or gauge) is also dependent upon location,
materials used, length of run, etc., so it must be determined
by a qualified electrician.
ELECTRICAL REQUIREMENTS
Refer to Ice Machine Model/Serial Plate for voltage/
amperage specifications.
VOLTAGE
The standard voltage for S/SV/SVI/NGF Series dispensers is
120VAC-60Hz. A power cord is provided with 120VAC-60Hz
models only. S/SV/SVI/NGF Series dispensers use a 1/7 hp
gearmotor.
MINIMUM CIRCUIT AMPERAGE CHART
Important
Due to continuous improvements, this information
is for reference only. Please refer to the dispenser
serial number tag to verify electrical data. Serial tag
information overrides information listed on this page.
Dispenser Voltage/Cycle
Minimum Circuit
Amps
S-150, S-200,
S-250, SV-150,
SV-175, SV-200,
SV-250, SV-150i,
SV-175i, SV-200i,
SV-250i, SV-250QD,
NGF-250,
NGF-250QD
115/60
2.8
220/50, 220/60,
240/50, 240/60
1.5
220-240/50
5
(with carb deck)
GROUNDING INSTRUCTIONS
n
Warning
The beverage/ice machine must be grounded in
accordance with national and local electrical codes.
This appliance must be grounded. In the event of
malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock. This appliance is equipped with a
cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
n
Warning
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
conductor with insulation having an outer surface that
is green with or without yellow stripes is the equipment
grounding conductor. If repair or replacement of
the cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.
Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood,
or if in doubt as to whether the appliance is properly
grounded. Do not modify the plug provided with the
appliance — if it will not fit the outlet, have a proper