Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
Part Number STH14 9/10 99
If brix adjustments are needed you will have to remove
the merchandiser to make the mechanical
adjustments. Please see PROGRAM MODE 2 in this
section for internal brixing instructions using the
control board and the Brixing Procedure for detailed
instructions on brixing the FRP-250.
CRUSHED OR CUBED DEFAULT
This selectable ice option will allow the unit to always
default to either cube or crushed ice or remain at the
last selection. This only applies to control boards
020000875 Rev 7 and up.
How to set default ice dispense setting
CUBE DEFAULT
1. Power on the unit by plugging in receptacle and
holding the cube button at the same time, cube
will flash 2 times. Unit will now change to cube 10
seconds after crush is selected.
CRUSH DEFAULT
2. Power on the unit by plugging in receptacle and
holding the crushed button at the same time,
crush will flash 2 times. Unit will now change to
crush 10 seconds after cube is selected.
LAST SELECTION DEFAULT
3. Power on the unit by plugging in receptacle and
holdding cube and crush at the same time, cube
and crush will flash 2 times. Unit will now remain
in selection of last request.
NOTE: If power is lost to the unit and then powered up
again the unit will retain the last setting and not return
to factory settings.
STH14.book Page 99 Thursday, September 23, 2010 3:35 PM