Installation Guide
Table Of Contents
- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
44 Part Number STH14 9/10
TYPICAL INTERNAL CARBONATION (IC) CEV
DISPENSING SYSTEM
NOTE: This is a simplified schematic to show the
basic operation of the beverage system.
TYPICAL EXTERNAL CARBONATION (AMBIENT)
CEV DISPENSING SYSTEM
NOTE: This is a simplified schematic to show the
basic operation of the beverage system.
Carbonator Tank
Post Chill Coil
Evaporator Coil (Ice Bank)
Dispenser
Countertop
B-I-B Syrup
Pump
B
a
g
-
I
n
-
B
o
x
S
y
r
u
p
C
a
r
t
o
n
CO
2
Cylinder
Tap Water (50 psi [3.4 bar])
125 gph
Pump
1/3 hp
Motor
Syrup
Tap Water (50 psi [3.4 bar])
CO
2
Syrup
Non-Carb
CO
2
To Carbonator Pump
To Ca rb
Ta nk
Post Chill Coil
Dispenser
Countertop
B-I-B Syrup
Pump
B
a
g
-
I
n
-
B
o
x
S
y
r
u
p
C
a
r
t
o
n
CO
2
Cylinder
Tap Water
Syrup
Tap Wat er
CO
2
Syrup
Carbonated
Water
Carbonator
Tank
Non-carbonated
Water
Evaporator Coil
(Ice Bank)
CO
2
STH14.book Page 44 Thursday, September 23, 2010 3:35 PM