User Manual
To fully back up your home’s essenal circuits, we recommend using the mPanel accessory
(not included) capable of supporng up to 4x circuits with a total load of 4000W/40A per single
MANGO POWER Union unit.
To test the home backup power supply and UPS (Uninterrupted Power Supply) features without the
mPanel, you can connect the MANGO POWER Union or Power Move with the gird and connect your
essenal circuits or devices with the output ports on top of the Power Move.
Turn on the Home Backup Breaker on the backside of the device and tap the UPS buon on the
Power Move’s touchscreen. The backup power supply will start working.
Now when a power outage occurs, the power supply for all the appliances connected to the backup
circuit will automacally and immediately begin powered by the
MANGO POWER Union and/or Power Move.
Please note this method (connecng via the output ports instead of the mPanel) can only support
2000W/20A for each AC port. If you use the MANGO POWER Union to connect several devices with
several AC ports for the test, make sure the total power needed is less than 4000W. If you want to
increase the overall capacity and back up all your home’s essenal circuits, we recommend
connecng several MANGO POWER Unions and running them in parallel.
Aer connecng the MANGO POWER Union to solar, the grid, or your home’s essenal circuits ,
your overall connecon will be as shown below:
Connect with Your Home’s Essenal Circuits
©2022 MANGO POWER. All rights reserved. MANGO POWER, the MANGO POWER logo, MANGO POWER Union, MANGO POWER Move, MANGO POWER Home,
MANGO POWER mPanel, MANGO POWER mSocket, MANGO POWER APP, and other trademarks or service names are the trademarks of MANGO POWER, Inc. Date subject to change.
07