Required AC Mains Cable 5x 6 mm² (< 50 m)
External Dimensions: Ø 18-25 mm
5x4 mm² (< 50 m)
External Dimensions: Ø 18-25 mm
Model
EVC04-AC7 Series
IEC Protection class Class - I
Vehicle
Interface
Socket Model Socket TYPE 2 (IEC 62196)
Cable Model Cable with TYPE 2 ( IEC 62196) Female Plug
Voltage and Current Rates 230VAC 50/60 Hz - 1-phase 32A
AC Maximum Charge Output 7.4kW
Idle Power
Consumption
3.5W
Required Circuit Breaker on
AC Mains
2P-40A MCB Type-C
Required Leakage Current Re-
lay on AC Mains (for products
which are not equipped with
RCCB Type A)
2P -40A - 30mA RCCB Type-A
Required AC Mains Cable 3x 6 mm² (< 50 m)
External Dimensions: Ø 13-18 mm
CONNECTIVITY
Ethernet
10/100 Mbps Ethernet (Standard with Smart Options)
Wi-Fi (Optional) Wi-Fi 802.11 a/b/g/n/ac
Bluetooth (Optional) BT 4.2 / BT 5.0
Celullar (Optional) LTE: B1 (2100 MHz), B3 (1800 MHz), B7 (2600 MHz), B8 (900 MHz), B20
(800 MHz), B28A (700 MHz)
WCDMA: B1 (2100 MHz), B8 (900 MHz)
GSM: B3 (1800 MHz), B8 (900 MHz)
OTHER FEATURES (Connected Models)
Diagnostics Diagnostics over OCPP
WebconfigUI
Software Update Remote software update over OCPP
WebconfigUI update
Remote software update with server
AUTHORIZATION
RFID ISO-14443A/B and ISO-15693