NOTE: For units ordered with optional convection baffles, installation of the baffle attachment
hardware must be done at this point. Connect the four (4) spacers to the body in the
holes provided. The hex head bolt should be to the inside. Tighten the hex head bolt to a
firm, tight condition using a 9/16" wrench. If the unit is a porcelain finished unit do not
over tighten the hex head bolts or damage to the porcelain finish may result.
8. Place the side wall refractory bricks back in the body section just as they came out of the
shipping carton. The tongue on the bottom of the bricks will fit into the groove provided in the
bottom fire bowl refractory casting. These bricks should all fit into place so that the tops of
the bricks are at the same level.
9. Unpack the screen carton and remove the gasketing material provided into the groove
located in the top of the side wall refractory bricks. Begin placing the gasketing material at
the opening fins connection point. Refer to Illustration Number 2. Care should be taken to
fill the groove around the circumference of the body section.
10. The top refractory casting may now be placed into position. Rotate the top refractory casting
so that the positioning grooves match the opening fins of the metal fireplace wall and top of
the body opening channel. This casting must fit down into the metal fireplace wall, and slight
movement may be necessary to insure the refractory casting is down evenly on the tops of
all the side wall refractory bricks. Also check to see that the top refractory casting has seated
onto the top of the opening channel completing the seal around the full circumference of the
body section.
11. The top metal hood will now drop on and seat into place.
12. Unpack the damper housing (Part Number DH 2) which also contains the connector shield
(Part Number CS 2).
13. Place the connector shield in the upper refractory opening. Refer to the illustrated sheet
packed with the damper housing and the connector shield for the proper installation.
Refer to Illustration No. 3.
14. Seat the damper housing (the flue pipe section with the damper plate and handle) into the