Use and Care Manual
Page 32 of 56
Checking the oil level
Check the oil with the pump level and cold.
Check the amount of oil through the level
gauge (A).
If necessary, top up with oil with the
characteristics specified in the ‘lubricants
table’.
To top up with oil proceed as described below.
1. Unscrew the plug (B) and pour oil in until it is
halfway up the level gauge (A).
2. Screw on the plug (B).
Position the machine in which the pump is
incorporated perfectly level, with the pump
slightly warm. Do not release oil into the
environment.
Dispose of spent oil in accordance with
statutory requirements.
To change the oil, proceed as described below.
1. Position a receptacle of suitable capacity to
collect the spent oil.
2. Unscrew the drain plug (A) and allow all the
oil to flow out.
3. Screw on the drain plug (A).
4. Unscrew the filler plug (B).
5. Pour in the fresh oil through the filter hole
until the correct level is reached.
6. Screw on the filler plug (B)